Ceramic durability

By using oxide ceramics, KROHNE employs a technically superior material for electromagnetic flowmeters (EMF) and pressure-measuring devices. This material offers long-term resistance to corrosive and abrasive media and does not leach. Additionally, these ceramics are resistant to temperature shocks and completely safe against gas permeation and leakage – providing a unique combination of properties for high-performance applications across all industrial sectors.

Highlights

  • High-resistance to abrasion

  • Suited for pastes and sludges with very high solid content

  • The helium leakage rate of ceramic including electrodes is less than 10-7 (hPa * l)/s, this means „gas-tight“

  • Vacuum-resistant up to 0 hPa

  • High mechanical strength and form stability

  • 0 % porosity (important for aggressive outgassing or toxic media)

  • Excellent surface quality and very low roughness (Ra < 0.8 µm)

  • Over 30 years of experience with industrial ceramic

  • Successful adaptions for various applications

Overview of KROHNE devices with oxide ceramics:

Flowmeters

Installation

Size/DN

Ceramic

Electrode

OPTIFLUX 5000

Flange

15 ... 300

FZM

CERMET, sintered-in

Sandwich

2.5 ... 15

FZM

CERMET, sintered-in

Sandwich

25 ... 100

FZT

Platinum pin electrode with plated head, pin sintered-in

BATCHFLUX 3100

Sandwich

2.5 ... 40

FZM

Platinum pin electrode with plated head, pin sintered-in

BATCHFLUX 5500

Sandwich

15

FZM

CERMET, sintered-in

OPTIFLUX 7000

Flange

2.5 ... 40

FTM

Capacitive, on ceramic tube

Sandwich

25

FZM

Capacitive, on ceramic tube

40 ... 100

FZT

Capacitive, on ceramic tube

Ceramics used:

FZT: FRIALIT® FZT: ZrO2-stabilised Al2O3, Bending strength = 460 MPa*, E-module = 360 GPa

FZM: FRIALIT® FZM: MgO partially stabilised ZrO2, Bending strength = 500 MPa*, E-module = 200 GPa

*1 MPa = 1 N/mm2

Pressure instruments

OPTIBAR PC 5060 Pressure transmitter

OPTIBAR­LC 1010 Immersion probe

Measuring ranges

0.025…100 bar

0...1 to 0...100 mH2O

Reference accuracy

<0.05 to 0.2% of URV

<±0.35% FSO

Process temperature

–40...+150°C

-40...+80°C

Process connections / material

Thread of more than 1/4¨, ASME flange, EN, DIN, JIS from DN15 in 316L, C276, Duplex, PVDF

Thread R1¨,

Flange DN50,

cable: TPE

Approvals

Ex ia, Ex d, SIL2/3

ATEX/IECEx Ex ia 1G,

drinking water

approvals (KTW, ACS)

Ceramics used:

Sapphire: 99.96 % Al2O3 ceramic, Bending strength = 630 MPa, E-module¬=¬406 GPa

Special features of flowmeters with ceramic liner:

  • Oxide ceramic is very resistant to acids and lyes. (Nitric acid and nitrohydrochloric acid or even hot concentrated hydrochloric acid cannot damage the oxide ceramic)

  • Adherence to the pressure equipment directive (DGLR)

  • Resistant to abrasive media: long service life especially compared to plastic liners

  • Fully vacuum-resistant

  • Dimensionally stable: high resistance to temperature shocks of up to 120 K and pressure stresses

  • Very high burst pressure/overload resistanct

  • No deposits/gumming on surface, diffusion tight and immune to leakage

  • Sintered-in CERMET electrodes

  • Leading metrological institutes use KROHNE ceramic EMFs as their master/ reference meter

Special features of pressure measuring devices with ceramic diaphragm

  • Suitable for pressure applications of up to 100 bar and 150 °C

  • Overload-proof up to 200 times the nominal measurement range

  • 100 % hydrogen resistance

  • 100 % diaphragm breakage detection

  • In the event of diaphragm breakage this is detected by the sensor electronics

  • Ten times harder than stainless steel

  • Absolutely vacuum-tight

Related products

Electromagnetic flowmeter for demanding volumetric filling applications for a wide range of container sizes

  • High accuracy measurement in process batching as well as cold or hot filling of conductive liquids, e.g. milk, fruit drinks with solid content, detergents etc.
  • With ceramic measuring tube and sintered electrodes for applications up to 16 bar / 232 psi
  • Flow tube conforms to EC1935/2004, FDA, GB 4806; 3A certified up to DN25 / 1"
  • Frequency output integrated, CANopen

Electromagnetic flowmeter for the volumetric filling of common container sizes

  • The most compact filling mag meter in the market for filling of conductive liquids, e.g. water, carbonized soft drinks etc.
  • Lightweight, economical design with ceramic flow tube for applications up to 8 bar / 116 psi
  • The DN15 / ½″ ceramic tube conforms to EC1935/2004, FDA, GB 4806
  • Frequency output integrated

Electromagnetic flow sensor for combination with IFC 100 and IFC 300 signal converters

  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN2.5…300 / ⅒…120"
  • Tube material: Ceramic

Pressure transmitter with ceramic diaphragm for basic pressure and level applications

  • Ultra-compact design with outstanding overload resistance, long-term stability and corrosion resistance
  • Capacitive measuring cell without fill fluid: recessed or front-flush ceramic diaphragm
  • Measuring range: 0.1...40 bar / 1.45...580 psi and max. +125°C / +257°F
  • Thread: G¼, G½, G¾ (male), also available in metal-free PVDF or PP-HT

Submersible level probe for water and wastewater applications

  • For continuous hydrostatic level measurement in basins and wells
  • With corrosion-resistant ceramic measuring cell
  • Level (water): 1…100 m / 3.3…328 ft; Pressure: 0.1…10 bar / 1.45…145 psi
  • 2-wire, 1 x 4…20 mA, HART®

Electronic differential pressure transmitter for level, differential pressure and density measurements

  • Integrated electronic differential pressure measurement
  • Alternative to diaphragm seal installations with long capillary lines
  • Integrated static pressure measurement for additional process information
  • 2-wire, 4…20 mA, HART®, FF, Profibus-PA, Bluetooth®